Designs and specifications see data sheet
Designs and specifications see data sheet
Pt100 temperature probe for use in laboratory,
medical,
air cabinet
Designs and specifications see data sheet
Precise measurement of the surface temperature in industrial processes. Sturdy stainless steel housing, protection class IP65. Broad temperature range from -40 to 2000 °C. Technical data and functions Several spectral ranges for a variety of materials and use cases....
Transmitter box with display and operating controls with analog output Surface temperature is measured over a wide range up to 600 / 1000 °C The probe head, thanks to its small dimensions, can be installed in cramped and restricted conditions Technical data and...
Other measuring ranges -20 to +500 °C High optical resolution Measuring spot 11.5 mm at distance 150 mm, in distant field 9:1 Designs and specifications see data sheet Technical data and functions Compact inexpensive infra-red probe head for measuring surface...
Pressure-sealed variant up to 16 bar Designs and specifications see data sheet Technical data and functions Compact sensor made from stainless steel Screw thread, for pressure pipes Option - adapter for compressed air pipes Capacitive digital sensor for humidity and...
Miniature sensor Designs and specifications see data sheet Technical data and functions Compact sensor, extremely small dimensions Wide operating temperature range Particularly suitable for measuring operations between PCBs, inside cases, in walls, ceilings, and...
❮ ❯ for humidity, temperature, atmospheric pressure Designs and specifications see data sheet Technical data and functions All sensors in 1 multi-sensor module: capacitive digital sensor for humidity and temperature, digital atmospheric pressure sensor....
Designs and specifications see data sheet Technical data and functions Measuring air flow velocity The vane anemometer is in practice unaffected by environmental variables such as pressure, temperature, density, or humidity. The design is compact - especially suitable...
Measuring range up 0.3 to 40 m/s Versions for ambient temperatures from -20 to +125 °C or -40 to +260 °C Maximum resolution 0.01m/s With permanently connected cable and ALMEMO® D6 connector Optional extensions Additional version with direction recognition Technical...
with integrated atmospheric pressure sensor for automatic atmospheric pressure compensation.
Designs and specifications see data sheet
Flow sensors for liquids in stainless steel without any moving parts, with integrated temperature measuring Designs and specifications see data sheet Technical data and functions Measuring section in stainless steel Application in systems with laminar flow, no...
For measuring the volume flow rate or for dosing tasks with large flow rates
Designs and specifications see data sheet
Optical probe for measurements of rotational speed, designed as retroreflective photoelectric sensor for photoelectric detection of rotational speeds Designs and specifications see data sheet Technical data and functions Optical probe for measurements of rotational...
Technical data and functions Independent, full digital acquisition of the true/effective values of an AC variable. Measuring signals with any course of a curve are digitised with 1kHz. Pure digital data transmission to the measuring instrument. Acquisition of the...
Technical data and functions Acquisition of the momentary, maximum, minimum and average value, plus transferring data of each measuring point scan to the ALMEMO® device. DC voltage or DC current signal are scanned with 1kHz. Pure digital data transmission to the...
Current transformers are used to acquire high alternating currents without contact and without interrupting the circuit. In principle, they consist of 2 separate transformator windings
Digital sensor for temperature atmospheric humidity atmospheric pressure Designs and specifications see data sheet Technical data and functions All relevant ambient parameters are measured with one sensor. Suitable for mounting on a wall or a mast Sensor cable up to...
Wind direction sensor for measuring the horizontal wind direction
Wind velocity sensor for measuring the horizontal wind velocity
Compact meteorological transducer for professional use Digital sensors for measuring wind, precipitation, air temperature, atmospheric humidity, atmospheric pressure Maintenance-free measuring procedures for wind and precipitation Forced-ventilated radiation-protected...
Designs and specifications see data sheet Adatlap: Digital sensor for temperature, atmospheric humidity, and atmospheric pressureAJÁNLATOT KÉREK
For determining the moisture content in granulated materials
such as wood chips,
wood pellets, and sawdust
❮ ❯ Heat Flow Plates Digital heat flow plate, with integrated temperature sensor for automatically correcting the heat flow plate’s temperature coefficient Designs and specifications see data sheet Technical data and functions Heat Flow Plates For...
This makes it less expensive but more robust with respect to asymmetrical overload Designs and specifications see data sheet Technical data and functions This measures the differential pressure in liquid and gaseous media indirectly using two absolute pressure...
Compact pressure sensors for industrial applications in liquid and gaseous substances Piezo-resistive, flexibly suspended silicone measuring cell in an oil-filled, all-welded special steel enclosure The stable mechanical construction provides a reliable protection for...
Compact pressure sensors for industrial applications in liquid and gaseous substances Designs and specifications see data sheet Technical data and functions Compact pressure sensors for industrial applications in liquid and gaseous substances. Piezo-resistive,...
Illuminance (V lambda)
UVA, UVB, UVC
Global radiation
IR
Global Radiation probe head
Illuminance measuring head
UVA Radiation probe head
UVB Radiation probe head
The sensitivity complies with the device class B as per DIN 5032 The measuring head is only suitable for indoor usage. Technical data and functions V- lambda sensors are used in the field of medical and/or biological research, for weather information and forecasting...
pH One-Bar Measuring Chains
pH Insertion Electrode
Redox-One-Bar Measuring Chain
Designs and specifications see data sheet
Oxygen sensor for O2 measurements in liquids Technical data and functions Determination of the conditions of life for fish and microorganisms in waters and fish tanks, biological treatment of municipal and industrial waste water, storage of organic liquids,...
Just one single probe for measuring conductivity from very low (10 µS/cm) up to very high levels (500 mS/cm)
4-contact graphite electrode with high linearity across the whole measuring range
❮ ❯ Designs and specifications see data sheet Technical data and functions Carbon monoxide probe Applications: For measurement, control and warnings in garages, for monitoring the air quality with respect to the maximum allowable concentration at work...
❮ ❯ Designs and specifications see data sheet Technical data and functions Digital carbon dioxide sensor Digital CO2 sensor with integrated signal processor All sensor characteristics and adjustment data are stored in the CO2 sensor itself. The unique...
Ammonia Nitrogen dioxide Nitrogen oxide Chlorine gas Sulfur dioxide Hydrogen sulfide Ethylene oxide Designs and specifications see data sheet Adatlap: Gas probe for various gasesAJÁNLATOT KÉREK